A plain-language glossary of the terms engineers, architects and energy modellers use when talking about thermal bridging and structural thermal breaks. Each definition links to more detail where it is available.

A B C D E G L M P R S T U

A

ASTM C177
Standard test method for steady-state heat flux and thermal conductivity using a guarded hot plate. STB-1 thermal conductivity (1.055 BTU·in/hr·ft²·°F) is measured to this method.
ASTM E84
Standard test for surface burning characteristics of building materials, reported as flame spread and smoke developed indices and grouped into classes A, B and C. STB-1 is rated Class A.

B

Bearing stress
The compressive force on a pad divided by the area it bears on, in psi or MPa. It sets the material and grade of a thermal break and whether creep needs checking. See the thermal break calculator.
Bolt bending
Bending in a bolt that carries shear across a gap or a soft layer. A thermal break pad lengthens the grip, so bolts in thermally broken connections are checked for combined shear, tension and bending.
Building envelope
The parts of a building that separate inside from outside: walls, roof, floors over unheated space, windows and doors, including their insulation and air and vapour barriers.

C

Cantilever
A member supported at one end only, such as a balcony or canopy beam projecting from the building. Cantilevers that pass through the envelope are classic thermal bridges.
Chi-value (χ)
Point thermal transmittance: the extra heat flow caused by a single discrete thermal bridge, such as one canopy beam or roof post, in W/K. Used in energy models alongside psi-values.
Clear-field transmittance
The heat flow through an area of wall or roof away from any interfaces or penetrations. Thermal bridges add to this baseline.
Compressive modulus
The ratio of compressive stress to strain in the elastic range. It controls how much a pad compresses under load. STB-1 has a compressive modulus of 830,000 psi (1″ thick).
Compressive strength
The stress at which a material fails in compression under test. STB-1 has a compressive strength of 48,000 psi (ASTM D695).
Condensation risk
The likelihood that a surface falls below the dew point of the surrounding air, so moisture condenses on it. Cold steel inside the envelope at a thermal bridge is a common source.
Continuous insulation
Insulation that runs uninterrupted across structural members, except for fasteners and service openings. Thermal bridges at balconies, shelf angles and posts interrupt it.
Creep
Gradual deformation of a material under sustained load. For STB-1, expected long-term deflection is 1.25 × the initial elastic deflection at bearing stresses up to 2,000 psi.

D

Dew point
The temperature at which air becomes saturated and water vapour begins to condense on a surface.
Dunnage
Steel framing on a roof that supports mechanical equipment, screens or solar arrays. Its posts penetrate the roof insulation and are usually thermally broken at the base plates.

E

Effective R-value
The overall thermal resistance of an assembly once thermal bridges are included. It is lower, sometimes much lower, than the nominal R-value of the insulation alone.
Embed plate
A steel plate cast into concrete with anchors, used as a connection point for steel balconies, canopies or angles. Thermal break pads are often placed between embeds and the attached steel.
End plate
A steel plate welded across the end of a beam so it can be bolted to another member. Thermally broken beam connections place a thermal break pad between two end plates.
Energy model
A computer simulation of a building’s energy use, used to show compliance with energy codes. Modern models include heat loss at thermal bridges using psi- and chi-values.
Engineer of record
The licensed engineer responsible for the structural design of a project, including thermally broken connections: bolt sizing, pad thickness and load checks.
Euroclass (EN 13501-1)
The European reaction-to-fire classification for construction products, from A1 (non-combustible) to F. STB-1 is classed Euroclass B.

G

Grip length
The total thickness of material clamped by a bolt. In a thermally broken connection it includes the thermal break pad, washers and bushings, and must be allowed for in bolt lengths.

L

Linear thermal transmittance
See psi-value.

M

Moment connection
A connection that transfers bending moment as well as shear, such as the support of a cantilevered beam. TBF should not be used in moment connections; STB-1 is used instead.

P

Permanent set
Deformation that remains after a load is removed. For STB-1, creep and permanent set together are limited to 5% of the original thickness.
Point thermal transmittance
See chi-value.
Prying action
Extra tension in bolts caused by the flexing of a connected plate, such as an end plate in a moment connection. Checked when sizing end plates and bolts.
Psi-value (ψ)
Linear thermal transmittance: the extra heat flow along a continuous thermal bridge, such as a shelf angle or slab edge, per unit length, in W/m·K.

R

R-value
Thermal resistance: how well a material or assembly resists heat flow, in ft²·°F·h/BTU. For a single layer, R = thickness ÷ thermal conductivity. STB-1 is about R-0.95 per inch.
Relieving angle
Another name for a shelf angle, emphasising its role in relieving the veneer below of the load above. See shelf angle thermal breaks.
RSI
The metric (SI) form of thermal resistance, in m²·K/W. RSI = R × 0.1761. See unit conversions.

S

Shear connection
A connection designed to transfer shear but not significant moment, such as a simply supported beam end or a hung canopy attachment.
Shelf angle
A steel angle attached at each floor to support masonry or stone veneer. It runs continuously around the building and is a major linear thermal bridge.
Slip-critical connection
A bolted connection designed to resist load by friction between the clamped surfaces. A thermal break plate in the grip changes the faying surfaces, so the design approach must be confirmed under the governing steel standard.
Snug-tight
A bolt tightened enough to bring the plies into firm contact, without specified pretension. Many thermally broken connections are designed snug-tight or pretensioned bearing.
Structural thermal break
A load-bearing, low-conductivity material or assembly placed where structure crosses the building envelope. It carries structural loads while interrupting heat flow. See What Is a Structural Thermal Break?

T

Thermal break
Any material or detail that interrupts a path of high heat flow. A structural thermal break must also carry significant loads.
Thermal break washer
A washer made from thermal break material, placed between the steel washer and the exterior steel so the bolt head or nut does not conduct heat to the cold plate.
Thermal bridge
A localized path of higher heat flow through the building envelope, typically where structure such as steel or concrete crosses the insulation layer.
Thermal Bushing
A sleeve of thermal break material fitted through a bolt hole in the exterior steel so the bolt shank does not touch the plate. Used with thermal break washers. See washers and bushings.
Thermal conductivity (k)
The rate at which heat passes through a material, in BTU·in/hr·ft²·°F (or W/m·K). Steel is about 374.5; STB-1 is 1.055; TBF ranges from 0.32 to 0.53.
Thermoset composite
A fibre-reinforced material whose resin cures permanently and does not soften when heated. STB-1 is a thermoset, reinforced composite.

U

U-value
Thermal transmittance of an assembly: the heat flow per unit area per degree of temperature difference, in BTU/hr·ft²·°F or W/m²·K. It is the inverse of the total R-value.

Put the terms to work: try the thermal break calculator, read the design guide, or convert units with the unit conversion page.

Request a Quote or Data Sheet

Send us your connection drawings, bolt schedule or load requirements and we will quote STB-1, TBF, washers and bushings cut and machined to your specification.

Call 800-580-4195 or use the form below. STB-1 typically ships in 5–7 days; TBF in as little as 3 days.