A
- ASTM C177
- Standard test method for steady-state heat flux and thermal conductivity using a guarded hot plate. STB-1 thermal conductivity (1.055 BTU·in/hr·ft²·°F) is measured to this method.
- ASTM E84
- Standard test for surface burning characteristics of building materials, reported as flame spread and smoke developed indices and grouped into classes A, B and C. STB-1 is rated Class A.
B
- Bearing stress
- The compressive force on a pad divided by the area it bears on, in psi or MPa. It sets the material and grade of a thermal break and whether creep needs checking. See the thermal break calculator.
- Bolt bending
- Bending in a bolt that carries shear across a gap or a soft layer. A thermal break pad lengthens the grip, so bolts in thermally broken connections are checked for combined shear, tension and bending.
- Building envelope
- The parts of a building that separate inside from outside: walls, roof, floors over unheated space, windows and doors, including their insulation and air and vapour barriers.
C
- Cantilever
- A member supported at one end only, such as a balcony or canopy beam projecting from the building. Cantilevers that pass through the envelope are classic thermal bridges.
- Chi-value (χ)
- Point thermal transmittance: the extra heat flow caused by a single discrete thermal bridge, such as one canopy beam or roof post, in W/K. Used in energy models alongside psi-values.
- Clear-field transmittance
- The heat flow through an area of wall or roof away from any interfaces or penetrations. Thermal bridges add to this baseline.
- Compressive modulus
- The ratio of compressive stress to strain in the elastic range. It controls how much a pad compresses under load. STB-1 has a compressive modulus of 830,000 psi (1″ thick).
- Compressive strength
- The stress at which a material fails in compression under test. STB-1 has a compressive strength of 48,000 psi (ASTM D695).
- Condensation risk
- The likelihood that a surface falls below the dew point of the surrounding air, so moisture condenses on it. Cold steel inside the envelope at a thermal bridge is a common source.
- Continuous insulation
- Insulation that runs uninterrupted across structural members, except for fasteners and service openings. Thermal bridges at balconies, shelf angles and posts interrupt it.
- Creep
- Gradual deformation of a material under sustained load. For STB-1, expected long-term deflection is 1.25 × the initial elastic deflection at bearing stresses up to 2,000 psi.
D
- Dew point
- The temperature at which air becomes saturated and water vapour begins to condense on a surface.
- Dunnage
- Steel framing on a roof that supports mechanical equipment, screens or solar arrays. Its posts penetrate the roof insulation and are usually thermally broken at the base plates.
E
- Effective R-value
- The overall thermal resistance of an assembly once thermal bridges are included. It is lower, sometimes much lower, than the nominal R-value of the insulation alone.
- Embed plate
- A steel plate cast into concrete with anchors, used as a connection point for steel balconies, canopies or angles. Thermal break pads are often placed between embeds and the attached steel.
- End plate
- A steel plate welded across the end of a beam so it can be bolted to another member. Thermally broken beam connections place a thermal break pad between two end plates.
- Energy model
- A computer simulation of a building’s energy use, used to show compliance with energy codes. Modern models include heat loss at thermal bridges using psi- and chi-values.
- Engineer of record
- The licensed engineer responsible for the structural design of a project, including thermally broken connections: bolt sizing, pad thickness and load checks.
- Euroclass (EN 13501-1)
- The European reaction-to-fire classification for construction products, from A1 (non-combustible) to F. STB-1 is classed Euroclass B.
G
- Grip length
- The total thickness of material clamped by a bolt. In a thermally broken connection it includes the thermal break pad, washers and bushings, and must be allowed for in bolt lengths.
L
- Linear thermal transmittance
- See psi-value.
M
- Moment connection
- A connection that transfers bending moment as well as shear, such as the support of a cantilevered beam. TBF should not be used in moment connections; STB-1 is used instead.
P
- Permanent set
- Deformation that remains after a load is removed. For STB-1, creep and permanent set together are limited to 5% of the original thickness.
- Point thermal transmittance
- See chi-value.
- Prying action
- Extra tension in bolts caused by the flexing of a connected plate, such as an end plate in a moment connection. Checked when sizing end plates and bolts.
- Psi-value (ψ)
- Linear thermal transmittance: the extra heat flow along a continuous thermal bridge, such as a shelf angle or slab edge, per unit length, in W/m·K.
R
- R-value
- Thermal resistance: how well a material or assembly resists heat flow, in ft²·°F·h/BTU. For a single layer, R = thickness ÷ thermal conductivity. STB-1 is about R-0.95 per inch.
- Relieving angle
- Another name for a shelf angle, emphasising its role in relieving the veneer below of the load above. See shelf angle thermal breaks.
- RSI
- The metric (SI) form of thermal resistance, in m²·K/W. RSI = R × 0.1761. See unit conversions.
S
- Shear connection
- A connection designed to transfer shear but not significant moment, such as a simply supported beam end or a hung canopy attachment.
- Shelf angle
- A steel angle attached at each floor to support masonry or stone veneer. It runs continuously around the building and is a major linear thermal bridge.
- Slip-critical connection
- A bolted connection designed to resist load by friction between the clamped surfaces. A thermal break plate in the grip changes the faying surfaces, so the design approach must be confirmed under the governing steel standard.
- Snug-tight
- A bolt tightened enough to bring the plies into firm contact, without specified pretension. Many thermally broken connections are designed snug-tight or pretensioned bearing.
- Structural thermal break
- A load-bearing, low-conductivity material or assembly placed where structure crosses the building envelope. It carries structural loads while interrupting heat flow. See What Is a Structural Thermal Break?
T
- Thermal break
- Any material or detail that interrupts a path of high heat flow. A structural thermal break must also carry significant loads.
- Thermal break washer
- A washer made from thermal break material, placed between the steel washer and the exterior steel so the bolt head or nut does not conduct heat to the cold plate.
- Thermal bridge
- A localized path of higher heat flow through the building envelope, typically where structure such as steel or concrete crosses the insulation layer.
- Thermal Bushing
- A sleeve of thermal break material fitted through a bolt hole in the exterior steel so the bolt shank does not touch the plate. Used with thermal break washers. See washers and bushings.
- Thermal conductivity (k)
- The rate at which heat passes through a material, in BTU·in/hr·ft²·°F (or W/m·K). Steel is about 374.5; STB-1 is 1.055; TBF ranges from 0.32 to 0.53.
- Thermoset composite
- A fibre-reinforced material whose resin cures permanently and does not soften when heated. STB-1 is a thermoset, reinforced composite.
U
- U-value
- Thermal transmittance of an assembly: the heat flow per unit area per degree of temperature difference, in BTU/hr·ft²·°F or W/m²·K. It is the inverse of the total R-value.
Put the terms to work: try the thermal break calculator, read the design guide, or convert units with the unit conversion page.
Request a Quote or Data Sheet
Send us your connection drawings, bolt schedule or load requirements and we will quote STB-1, TBF, washers and bushings cut and machined to your specification.
Call 800-580-4195 or use the form below. STB-1 typically ships in 5–7 days; TBF in as little as 3 days.